The Water and Wastewater Equipment Company inclined plate clarifier is designed for ease of maintenance and when operated properly will require minimal control and operator time. Periodic maintenance of the inclined plate clarifier should be done to assure proper operation. The following steps can aid in the inclined plate clarifier operation and control:
Cleaning inclined plate clarifier:
-
Open sludge draw-off valve for three (3) minutes on the inclined plate clarifier, until sludge is totally evacuated and water is predominate discharge. Note: SLUDGE TANK SHOULD BE EMPTY!
-
Open plate pack drain on the side of the inclined plate clarifier.
-
Using a pressure nozzle on a hose, hose down all visible surfaces, weirs, launderers and flow chamber of collected, caked solid deposits in the inclined plate clarifier.
-
Hose down plate pack and inclined plate clarifier area of all visible solids.
-
Once thoroughly rinsed, close plate pack drain. The inclined plate clarifier is now ready for normal operation.